PIR Ready VT7200 Series
24 Vac Low Voltage Zoning Thermostats
For Commercial HVAC Applications
(Issue Date June 12, 2008 – 028-0190_R2)
Product overview
The VT7200 PI thermostat family is specifically designed for zoning applications.
Typical applications include local hydronic reheat valve control and pressure
dependent VAV with or without local reheat. The product features a backlit LCD display
with dedicated function menu keys for simple operation. Accurate temperature control
is achieved due to the product’s PI proportional control algorithm, which virtually
eliminates temperature offset associated with traditional, differential-based
thermostats. Models are available for 3 point floating and analog 0 to 10 Vdc control. In
addition remote room sensing is available.
They all contain an SPST auxiliary switch that can be used to control lighting or
auxiliary reheat. 3 additional inputs are also provided for monitoring and / or various
advanced functions.
All devices are also available with Echelon, BACnet MS-TP or Zigbee wireless network adapter.
The thermostats are also compatible with the new Viconics PIR cover accessories. Thermostats equipped
with a PIR cover provide advanced active occupancy logic, which will automatically switch occupancy levels
from Occupied to Stand-By and Unoccupied as required by local activity being present or not. This advanced
occupancy functionality provides advantageous energy savings during occupied hours without sacrificing
occupant comfort. All thermostats can be ordered with or without a factory installed PIR cover ( see ordering
notes below ).
The additional following documents are available at: www.viconics.com
PIR application information and examples, are available on document: APP-PIR-Guide-Exx
PIR cover installation information is available on document: PIR Cover Installation-Exx
Information on the LON models (VT7200x5000E), is available on document ITG-VT7200-PIR-LON-Exx
Information on the BACnet models (VT7200x5000B), is available on document ITG-VT7300-PIR-BAC-Exx
Information on the Wireless models (VT7200x5000W), is available on documents: ITG-VWG-40-BAC-Exx and
LIT-VWG-40-SETUP-Exx
Models available
Viconics Part Numbers
VT7200C5000
VT7200C5000B (BACnet)
VT7200C5000E (Echelon)
VT7200C5000W (Wireless)
VT7200F5000
VT7200F5000B (BACnet)
VT7200F5000E (Echelon)
VT7200C5000W (Wireless)
Control Outputs 2 x Tri-state floating 2 x Analog 0 to 10 Vdc
1 x Auxiliary or reheat contact 1 x Auxiliary or reheat contact
Ordering Information Notes:
Thermostats can be ordered with a factory installed PIR cover. Please use (5500) extension instead of the (5000) only
extension.: Ex. VT7200C5500E.
Thermostats ordered without a PIR cover can be retrofitted with a separate PIR accessory cover afterwards
when required
Features and benefits
Features Benefits
Advanced occupancy functions Through the network or smart local occupancy
sensing
Ready for PIR accessory cover
Fully integrated advanced occupancy functionality with
a PIR accessory cover
3 configurable inputs Adds functionality
Pre-configured sequences of operation One model meet more applications
Reduces project delivery cost
Unique configuration setup utility Minimizes parameter tampering
Lockable keypad Tamper proof, no need for thermostat guards
Available for 24 Vac On/Off, Floating or Analog
control
Meet advanced applications requirements
Auxiliary output Can be used for lighting or reheat
Available with various open industry standards
communication adapters
Adds network integration functionality for additional
savings
028-0190R2-LIT-VT7200-PIR-E02.doc www.viconics.com / sales@viconics.com
Vista de página 0
1 2 3 4 5 6 ... 14 15

Resumo do Conteúdo

Página 1 - PIR Ready VT7200 Series

PIR Ready VT7200 Series 24 Vac Low Voltage Zoning Thermostats For Commercial HVAC Applications (Issue Date June 12, 2008 – 028-0190_R2) Product overvi

Página 2

10Installer configuration parameter menu Configuration can be done through the network or locally at the thermostat. • To enter configuration, pres

Página 3

11 Configuration parameters Default value Significance and adjustments Com Addr Thermostat networking address Default value = 4 Range is: 0 to 254 C

Página 4

12 BI2 Binary input no.2 configuration Default value = None (None): No function will be associated with the input (Door Dry) Door contact & Moti

Página 5 - 24 V~ Com

13 SeqOpera Sequence of operation Default is: Sequence #1 Single output application (Out1Conf) = 2.0) Dual output application (Out1Conf) = 4.0) 0 = C

Página 6

14 aux cont Auxiliary contact function & configuration Default value = 0 Not Used 0 Aux contact function used for reheat IF SEQUENCE IS SET TO RE

Página 7

153.38" [86 mm]1.13" [29 mm]4.94" [125 mm] Specifications Thermostat power requirements: 19-30 Vac 50 or 60 Hz; 2 VA Class 2 Oper

Página 8

Installation • Remove security screw on the bottom of thermostat cover. • Open up by pulling on the bottom side of thermostat. • Remove Assembly

Página 9

3Programmable BI/UI inputs overview Binary input #1 can be configured for the following functions: 1. (None): No function will be associated with

Página 10

4 Terminal identification Generic wiring Viconics Part Numbers VT7200C5x00(x) Viconics number VT7200F5x00(x)Description

Página 11 - Significance and adjustments

5Main outputs wiring typical for valves Single output applications Dual output applications On-Off control VT7200C5x00(x) Floating control VT7

Página 12

6 Schematic Wiring Settings Pressure dependent VAV cooling / heating with changeover: VT7200C5x00(x) Floating actuator Mandatory • Out1Conf = 2.0

Página 13

7 Schematic Wiring Settings Heating or cooling hydronic valve control: VT7200C5x00(x) Floating actuator Mandatory • Out1Conf = 2.0 • CntrltTyp =

Página 14

8 Remote sensor accessories Model no. Description S3010W1000 Wall mounted temperature sensor S3020W1000 Wall mounted temperature sensor with o

Página 15

9 Programming and status display instructions Status display The thermostat features a two-line, eight-character display. There is a low level b

Comentários a estes Manuais